[Header]	
Customer Name	ILLUMINA, INC.
Product Type	15034056
Date Manufactured	08/04/2013
Lot	WO0000109323892
DesignStudio ID	25431
Target Plexity	117
	
[Probes]
Gene Name	Transcript ID	Assay ID	Left Exon	Right Exon	Species	Build ID	Chromosome	Start Position	End Position	ULSO Sequence	ULSO Genomic Hits	DLSO Sequence	DLSO Genomic Hits	Probe Strand	Designer	Design Score	SNP Masking	Labels
ABL1	NM_007313	6607434	1	2	Homo sapiens	hg19	chr9	133729590	133730231	GGCCAGTGGAGATAACACTCTAAGCATA	1	AGGCTATAATCACAATGGGGAATGG	1	PLUS	ILLUMINA	1.856	false	
AIFM1	NM_001130847	6613574	16	15	Homo sapiens	hg19	chrX	129263979	129263577	GGAACATCTTTAACCGAATGCCAATAGC	2	TCATTAAGGACGGTGAGCAGCATGAA	1	MINUS	ILLUMINA	1.937	false	
AKT1	NM_001014432	6694989	4	3	Homo sapiens	hg19	chr14	105246457	105243085	GTGAGGCTCCCCTCAACAACTTCTCT	1	GTGCCAGCTGATGAAGACGGAG	9	MINUS	ILLUMINA	1.38	false	
APAF1	NM_181861	6686842	3	4	Homo sapiens	hg19	chr12	99043428	99052978	TGCAGAAGCTGTTAGAGATCATTCCC	1	GGGAGTGCATTGGGTTTCAGTTGGGAAA	1	PLUS	ILLUMINA	1.897	false	
AVEN	NM_020371	6766741	2	1	Homo sapiens	hg19	chr15	34295265	34168171	GAACAGATTTCAGTGTCCTCCTTAGCTC	1	GGACTCATTCTCACAGTTCCGGTTT	1	MINUS	ILLUMINA	1.854	false	
BAD	NM_032989	6717565	3	2	Homo sapiens	hg19	chr11	64039119	64037787	GGAGGATGAGTGACGAGTTTGTGGA	2	AGGGACTTCCTCGCCCGAAGAG	2	MINUS	ILLUMINA	1.3	false	
BAG1	NM_004323	6814755	3	2	Homo sapiens	hg19	chr9	33261119	33258999	AAGATGGTTGCCGGGTCATGTTAATTG	2	TCCACAGGAAGAGGTTGAACTAAAGAAG	1	MINUS	ILLUMINA	1.968	false	
BAG3	NM_004281	6702665	2	3	Homo sapiens	hg19	chr10	121432140	121436013	GTGTGCACACCGTGGTCGACAG	3	ATCGAGAAACTGCACCTGTTTCCCA	1	PLUS	ILLUMINA	1.314	false	
BAG4	NM_004874	6775167	3	4	Homo sapiens	hg19	chr8	38066760	38067554	CTTCACCCCCAGTCCAGCAGCCCAA	6	CTTCATACCCCTATAGCCAATCAGA	2	PLUS	ILLUMINA	1.604	false	
BAK1	NM_001188	6828357	1	0	Homo sapiens	hg19	chr6	33547830	33545374	CCACCCGGGTTGGGCCAGGATC	10	TCCACTGAGACCTGAAAAATGGCTTC	3	MINUS	ILLUMINA	1.334	false	
BAX	NR_027882	6728035	0	1	Homo sapiens	hg19	chr19	49458191	49458834	CGGGTCCGGGGAGCAGCCCAGA	11	ACCAGCTCTGAGCAGATCATGAAGA	5	PLUS	ILLUMINA	1.205	false	
BCL10	NM_003921	6712588	1	0	Homo sapiens	hg19	chr1	85742004	85736561	AGGACCTCACTGAAGTGAAGAAGGA	1	GCCTTAGAAAATTTACGTGTATACCTGTG	1	MINUS	ILLUMINA	1.771	false	
BCL2	NM_000633	6665875	1	0	Homo sapiens	hg19	chr18	60986441	60986151	TTGACAGAGGATCATGCTGTACT	3	CAGAGGAAGTAGACTGATATTAACAATACT	1	MINUS	ILLUMINA	1.37	false	
BCL2L11	NM_138623	6656440	0	1	Homo sapiens	hg19	chr2	111878737	111881341	ACTCTGACTCTCGGACTGAGAAA	8	AAGACCAAATGGCAAAGCAACCTTCTG	1	PLUS	ILLUMINA	1.622	false	
BCL2L13	NM_015367	6753678	0	1	Homo sapiens	hg19	chr22	18121623	18138456	CATCTCTTCTGGGGCAGGGGCCA	10	GTTTTACACATCCATAAGTAGACCTTTTT	1	PLUS	ILLUMINA	1.368	false	
BCL2L2	NM_004050	6813208	2	3	Homo sapiens	hg19	chr14	23777376	23778059	CTGGCTGACTGGATCCACAGCAGT	3	AGCTCTATACGGGGACGGGGCCCT	1	PLUS	ILLUMINA	1.321	false	
BCL3	NM_005178	6793284	1	2	Homo sapiens	hg19	chr19	45254610	45259517	CCACCCGTGCAGATGAGGACGGAGACA	1	CTCCATATTGCTGTGGTGCAGGGTA	1	PLUS	ILLUMINA	1.659	false	
BCLAF1	NM_014739	6630113	9	8	Homo sapiens	hg19	chr6	136590607	136589448	TTACAAGGAATACAAATCTTACAAAGATGA	2	ACATAAAAGAGAGCAAGATCATTCTCG	1	MINUS	ILLUMINA	1.67	false	
BFAR	NM_016561	6789292	0	1	Homo sapiens	hg19	chr16	14726841	14738160	AATAATGGCCCGGTTGGCCCGG	1	TTAATGATGTTTTGCAGCAGTTTTCTACG	1	PLUS	ILLUMINA	1.298	false	
BID	NM_197966	6680411	5	4	Homo sapiens	hg19	chr22	18220813	18218316	ACGCACCTACGTGAGGAGCTTA	3	GACAGTTCCAGAAGTGTGACTGGCTAA	1	MINUS	ILLUMINA	1.461	false	
BIK	NM_001197	6713623	1	2	Homo sapiens	hg19	chr22	43520157	43523744	GGACTTCGATTCTTTGGAATGCATGG	1	GGCTGGCCTGCATCGGGGACGAGAT	1	PLUS	ILLUMINA	1.622	false	
BIRC2	NM_001166	6703614	3	4	Homo sapiens	hg19	chr11	102233673	102234426	ATTCAAGGTAGATATCCTCATCTTCTTG	1	TGTTGTCAACTTCAGATACCACTGGAG	1	PLUS	ILLUMINA	1.938	false	
BIRC3	NM_182962	6764041	5	6	Homo sapiens	hg19	chr11	102199642	102201757	AGACAGCCCAGGAGATGAAAATGCA	2	TATCCATTTTGAACCTGGAGAAGACCA	1	PLUS	ILLUMINA	1.881	false	
BIRC5	NM_001012271	6629354	3	4	Homo sapiens	hg19	chr17	76212830	76219586	AAACTGGACAGAGAAAGAGCCAAGAAC	1	CAACAATAAGAAGAAAGAATTTGAGGAAAC	1	PLUS	ILLUMINA	1.717	false	
BIRC6	NM_016252	6605793	72	73	Homo sapiens	hg19	chr2	32836625	32842830	GTCTCACCATGCAGCAGCTCTCAA	4	CTCCGCGAAGAGTTGCTGAAACTT	1	PLUS	ILLUMINA	1.506	false	
BIRC7	NM_139317	6666105	0	1	Homo sapiens	hg19	chr20	61867769	61869292	GCTGGCTGCTGCCGGCTTCTTCCACA	1	TGAGGTGCTTCTTCTGCTATGGG	3	PLUS	ILLUMINA	1.345	false	
BNIP2	NM_004330	6716786	9	8	Homo sapiens	hg19	chr15	59961123	59956280	GGAATACGTTGGCATACCAGAATGCA	1	CTTAATGGAAAACAAGATGAACCGAAA	1	MINUS	ILLUMINA	1.925	false	
BNIP3	NM_004052	6781677	5	4	Homo sapiens	hg19	chr10	133784169	133782046	TCTCTCATTTGCTGGCCATCGGATT	9	GATCTATATTGGAAGGCGTCTGACAACC	3	MINUS	ILLUMINA	1.85	false	
BNIP3L	NM_004331	6776815	2	3	Homo sapiens	hg19	chr8	26252788	26265551	AATGCACACCAGCAGGGACCATA	2	AAGAAGTTGTAGAAGGAGAGAAGGAAGTC	1	PLUS	ILLUMINA	1.515	false	
BOK	NM_032515	6639260	2	3	Homo sapiens	hg19	chr2	242501864	242509563	GCCGTGGCTGGCCACATCTTCTCT	1	GCATCACGTGGGGCAAGGTGGTGT	2	PLUS	ILLUMINA	1.314	false	
BRAF	NM_004333	6678950	1	0	Homo sapiens	hg19	chr7	140624402	140549980	GGCCTCTTCGGCTGCGGACCCTGCCATT	2	TGGAATATCAAACAAATGATTAAGTTGACA	1	MINUS	ILLUMINA	1.336	false	
CARD6	NM_032587	6718671	1	2	Homo sapiens	hg19	chr5	40843779	40852317	CATTGGAGGAGGAACAGGAGAAAAGT	1	GTTTAAAGATGTCCTGTTATGTTTGAACA	1	PLUS	ILLUMINA	1.809	false	
CARD9	NM_052814	6800360	1	0	Homo sapiens	hg19	chr9	139268016	139266510	CTGCAGTGCAGGTGGCTCCTGGAAGA	1	AGGCCATGTCGGACTACGAGAACGAT	1	MINUS	ILLUMINA	1.723	false	
CASP1	NM_033292	6735042	9	8	Homo sapiens	hg19	chr11	104896981	104896300	AAGGAAACTGTATGAATGTCTGTGGGC	4	AAGTGAAGAGATCCTTCTGTAAAGGTT	1	MINUS	ILLUMINA	1.98	false	
CASP10	NM_032977	6713238	0	1	Homo sapiens	hg19	chr2	202047997	202050520	TTACTTCCAGAAGATTGGTGGAGCTTG	1	CTGGCCATGAAATCTCAAGGTCAACA	1	PLUS	ILLUMINA	1.966	false	
CASP14	NM_012114	6769691	0	1	Homo sapiens	hg19	chr19	15160422	15163051	AACTTGGCCTTGAGGAACAGCTG	3	AGGGTGCTGAGAGCCGGGACTCACAA	1	PLUS	ILLUMINA	1.423	false	
CASP2	NM_001224	6695810	1	2	Homo sapiens	hg19	chr7	142988755	142989436	TCACCTTGGAAATGAGGGAGCTCAT	1	CAGCCAGAATGTGGAACTCCTCAACTT	1	PLUS	ILLUMINA	1.867	false	
CASP3	NM_004346	6622272	7	6	Homo sapiens	hg19	chr4	185552223	185550612	CCGACTTCTTGTATGCATACTCCACA	1	AATTCAAAGGATGGCTCCTGGTTCATC	1	MINUS	ILLUMINA	1.966	false	
CASP4	NM_033306	6612269	6	5	Homo sapiens	hg19	chr11	104819290	104817876	GACTTCATTGCTTTCTGCTCTTCAACG	3	GCACAATGGGCTCTATCTTCATC	3	MINUS	ILLUMINA	1.623	false	
CASP5	NM_004347	6800318	9	8	Homo sapiens	hg19	chr11	104866501	104865047	AAGAGATTTCTACCTCTTTCCTGGCAA	3	AAACCACAGGCAGCCCAGCCCTCCTCT	2	MINUS	ILLUMINA	1.763	false	
CASP6	NM_001226	6764405	5	4	Homo sapiens	hg19	chr4	110615715	110612130	GCCTGGTTGGAAAACCCAAGATATT	2	GGAAACCAGCACGATGTGCCAGTCATT	1	MINUS	ILLUMINA	1.833	false	
CASP7	NM_033340	6688018	1	2	Homo sapiens	hg19	chr10	115457330	115480828	AGACCGGTCCTCGTTTGTACCGT	1	TGTCACCATGCGATCCATCAAGA	2	PLUS	ILLUMINA	1.232	false	
CASP8	NM_033355	6847575	3	4	Homo sapiens	hg19	chr2	202136310	202137388	AGGAAATCTCCAAATGCAAACTGGATG	1	ACCTGCTGGATATTTTCATAGAGATGG	1	PLUS	ILLUMINA	1.994	false	
CASP8AP2	NM_012115	6769661	5	6	Homo sapiens	hg19	chr6	90566884	90571888	CGCAAGGATGAAGAAATAAGTAATCTTCAC	1	ACATTTTCGAAATAATCATAAAACTGCAA	1	PLUS	ILLUMINA	1.535	false	
CASP9	NM_032996	6776537	8	7	Homo sapiens	hg19	chr1	15820417	15819505	CTCTGAAGACCTGCAGTCCCTCCT	2	TCGCTAATGCTGTTTCGGTGAAAGG	1	MINUS	ILLUMINA	1.599	false	
CD27	NM_001242	6816931	0	1	Homo sapiens	hg19	chr12	6554369	6554627	AAAGCTGTGCTGCCAGATGTGTGA	3	GAAGGACTGTGACCAGCATAGAAAG	1	PLUS	ILLUMINA	1.645	false	
CD40	NM_001250	6615876	1	2	Homo sapiens	hg19	chr20	44750507	44750899	AACAGTCAGTGCTGTTCTTTGTGCCA	1	AGAAACTGGTGAGTGACTGCACAGA	1	PLUS	ILLUMINA	1.845	false	
CD70	NM_001252	6775017	1	0	Homo sapiens	hg19	chr19	6590879	6590121	GCAGCAGCTGCCGCTCGAGTCACTT	1	TGGGACGTAGCTGAGCTGCAGCTGAAT	1	MINUS	ILLUMINA	1.596	false	
CFLAR	NM_003879	6709279	3	4	Homo sapiens	hg19	chr2	202000796	202005108	CCTGAAGACAAAAATCCAGAAGTACAAGC	1	AAGGAGCAGGGACAAGTTACAGGAAT	1	PLUS	ILLUMINA	1.861	false	
CIDEA	NR_036468	6751245	1	2	Homo sapiens	hg19	chr18	12262936	12264346	ATGGCAAGCAGCCTGCAGGAGCTCAT	1	CATCGCTACCGGACTGGTCACTCT	1	PLUS	ILLUMINA	1.555	false	
CIDEB	NM_014430	6612266	6	5	Homo sapiens	hg19	chr14	24775178	24774945	GGACTTGGCCCAAAGAAAGTACTCA	2	CTCCTTCGTTGGACCTCCACACT	1	MINUS	ILLUMINA	1.487	false	
CRADD	NM_003805	6838464	0	1	Homo sapiens	hg19	chr12	94071220	94072573	CCCCGCCCCAAAGATACGTGGTT	3	GAAATGGAGGCCAGAGACAAACAAGT	2	PLUS	ILLUMINA	1.535	false	
CYCS	NM_018947	6764133	1	0	Homo sapiens	hg19	chr7	25164849	25163712	GAGTGTTCGTTGTGCCAGCGACTAAAA	2	TATGGGTGATGTTGAGAAAGGCAAGAAG	31	MINUS	ILLUMINA	1.946	false	
DAPK1	NM_004938	6827954	24	25	Homo sapiens	hg19	chr9	90318092	90321087	ACCTCAGGCGCATTGCTCAGCA	3	TGAAACAGTTCAGGACGTGCTGCT	1	PLUS	ILLUMINA	1.214	false	
DAXX	NM_001350_4	6675987	3	2	Homo sapiens	hg19	chr6	33288543	33288335	GGCTGCCACCTCACAGATGACTATA	1	CTGCACTATCAGATCCTGTGTTGGC	1	MINUS	ILLUMINA	1.735	false	
DEDD	NM_032998	6621603	5	4	Homo sapiens	hg19	chr1	161092897	161092270	TGACACCAGATCCCAAGGAGAAGCAGA	1	CGGGCTGAATACTGCCAGCATGAGACT	1	MINUS	ILLUMINA	1.856	false	
DEDD2	NM_133328	6841178	3	2	Homo sapiens	hg19	chr19	42719313	42713960	AAATTCTCAGCAGGGTCAGTGGGA	4	ACCAAGCGGCAGCGGCGGAGTC	2	MINUS	ILLUMINA	1.114	false	
DFFA	NM_004401	6690106	3	2	Homo sapiens	hg19	chr1	10527279	10523636	AGCATCATCCTCCTATCAGAGGAGGA	1	CTGCTCAGACCTGGCTCAGGAACTA	4	MINUS	ILLUMINA	1.79	false	
DIABLO	NR_024600	6805154	5	4	Homo sapiens	hg19	chr12	122701338	122701091	GTGTGGCAGGTGATCATAGGAGC	1	CAAGAGTACTTGAAGCTGGAAACCAC	1	MINUS	ILLUMINA	1.57	false	
FADD	NM_003824	6974570	1	1	Homo sapiens	hg19	chr11	70052845	70052899	TAGTTGGAAAGTTGGAACCGTGTCCA	1	AGAAGGAATCTGTGCAGATGAGCAGT	2	PLUS	ILLUMINA	1.933	false	
FAS	NM_000043	6886514	8	NA	Homo sapiens	hg19	chr10	90774742	90774797	GCAGAATTTAAATAAGGCTCTACCTCA	1	CCTTTGCACAGTTTATTGGTGTCAT	2	PLUS	ILLUMINA	1.867	false	
FASLG	NM_000639	6690598	2	3	Homo sapiens	hg19	chr1	172633502	172634789	GGAGCTGAGGAAAGTGGCCCATTTAA	2	CAAGTCCAACTCAAGGTCCATGCCTCT	1	PLUS	ILLUMINA	1.903	false	
HIP1	NM_005338	6761552	10	9	Homo sapiens	hg19	chr7	75192524	75192336	AAGCGGCTCATTCAGATCCCCCA	2	CTGCGAGCCTCAGCCCTGTCAGAACATAT	1	MINUS	ILLUMINA	1.392	false	
HMGB1	NM_002128	6680865	4	3	Homo sapiens	hg19	chr13	31036717	31035641	TTATGAAAAGAAGGCTGCGAAGCTG	36	ATATTGCTGCATATCGAGCTAAAGGAAAG	34	MINUS	ILLUMINA	1.78	false	
HRK	NM_003806	6681306	1	0	Homo sapiens	hg19	chr12	117318808	117299243	GCCGAGACCCAGCCGGAGCGAGCAACA	1	TGGTGAAAACCCTGTGTCCTTGGAGAA	2	MINUS	ILLUMINA	1.605	false	
HSP90B1	NM_003299	6657454	0	1	Homo sapiens	hg19	chr12	104324310	104325338	TGCTGGGCCTCTGCTGCGTCCTGCTGA	1	TGACGATGAAGTTGATGTGGATGGTAC	2	PLUS	ILLUMINA	1.682	false	
IGF1R	NM_000875	6821131	2	3	Homo sapiens	hg19	chr15	99434836	99440026	CCTCGGGCTTCATCCGCAACGG	1	TTGTGAAGGTCCTTGCCCGAAGGTCT	1	PLUS	ILLUMINA	1.306	false	
IKBIP	NM_201612	6720992	1	0	Homo sapiens	hg19	chr12	99038333	99028148	GCTGTCGCTGGGGACGTGCCTG	5	GTCAGAAAAATTTGCAAAGGTGGAAAACC	1	MINUS	ILLUMINA	1.246	false	
IKBKB	NR_040009	6639731	5	6	Homo sapiens	hg19	chr8	42162763	42163901	AAACATCGTCCTGCAGCAAGGAGAA	1	ATTGACCTAGGATATGCCAAGGAGCT	2	PLUS	ILLUMINA	1.85	false	
IKBKG	NM_003639	6701312	1	2	Homo sapiens	hg19	chrX	153780377	153784407	TGCCTGGAGGAGAATCAAGAGCT	9	CATCCGGCAGAGCAACCAGATTCT	2	PLUS	ILLUMINA	1.364	false	
IL10	NM_000572	6739478	3	2	Homo sapiens	hg19	chr1	206944279	206943213	GACCCTCAGGCTGAGGCTACGG	9	CATCGATTTCTTCCCTGTGAAAACAAG	1	MINUS	ILLUMINA	1.403	false	
IL1A	NM_000575	6634703	1	0	Homo sapiens	hg19	chr2	113542054	113541329	AGGGAGTCATTTCATTGGCGTTTGAG	1	AGTCAAGATGGCCAAAGTTCCAGACA	1	MINUS	ILLUMINA	1.933	false	
LTA	NM_000595_3	6914026	3	NA	Homo sapiens	hg19	chr6	31541751	31541808	TGGGGCCTAGATCCACACACAGAGGAA	1	GCACATGGAGGAGCTTGGGGGATGA	1	PLUS	ILLUMINA	1.689	false	
LTB	NM_002341_3	6849823	1	0	Homo sapiens	hg19	chr6	31550058	31549608	TAGTGCCCCAGGATCAGGGAGGACT	2	CGGAGACGGCCGACCCCGGGGCACA	1	MINUS	ILLUMINA	1.228	false	
LTBR	NM_002342	6732979	2	3	Homo sapiens	hg19	chr12	6494285	6494425	CTGCCAGCTGTGCCGCCCCTGTGA	2	TCGAGGAGATTGCCCCCTGCACAA	1	PLUS	ILLUMINA	1.24	false	
MCL1	NM_001197320	6687379	3	2	Homo sapiens	hg19	chr1	150550754	150549939	CAAAACGGGACTGGCTAGTTAAACAAAG	1	GGGTTTGTGGAGTTCTTCCATGTAGA	2	MINUS	ILLUMINA	1.941	false	
MYC	NM_002467	6670402	1	2	Homo sapiens	hg19	chr8	128751231	128752671	TGAGGAGACACCGCCCACCACCA	4	AGGAACAAGAAGATGAGGAAGAAATCG	1	PLUS	ILLUMINA	1.518	false	
NAIP	NM_004536	6834644	16	15	Homo sapiens	hg19	chr5	70269988	70266263	AGACTTTGAATGATGACAGCGTGGTG	2	AGCAATCAGTGGAGGTTTCCAGAAAC	2	MINUS	ILLUMINA	1.935	false	
NFKB1	NM_003998	6777413	5	6	Homo sapiens	hg19	chr4	103488264	103498066	ACTGCTGGACCCAAGGACATGGT	5	AACCTGGGTATACTTCATGTGACAAAG	1	PLUS	ILLUMINA	1.594	false	
NFKB2	NM_002502	6830412	19	20	Homo sapiens	hg19	chr10	104161248	104161530	CCACCCCTGACCCCGCCCAGCCCAGCA	4	GACTGTCACTTGGTGATACAGCT	3	PLUS	ILLUMINA	1.113	false	
NFKBIA	NM_020529	6810000	5	4	Homo sapiens	hg19	chr14	35871626	35871239	GAGTTCACGGAGTTCACAGAGGA	4	CCCTATGATGACTGTGTGTTTGGAG	2	MINUS	ILLUMINA	1.505	false	
NOD1	NM_006092	6622684	13	12	Homo sapiens	hg19	chr7	30469024	30465296	GCGTTACAGAGCAACACTGGCATAA	1	CTAAATGGAAACCTGATAAAACCAGAGGAG	1	MINUS	ILLUMINA	1.66	false	
NOL3	NM_001185058	6816005	4	5	Homo sapiens	hg19	chr16	67208807	67208991	AGAGCCCGAGCCCGACTTCGAGGAAA	1	AGCTCTGACAGGCGGTGCCCCGCCCAT	1	PLUS	ILLUMINA	1.407	false	
PEA15	NM_003768	6787860	1	2	Homo sapiens	hg19	chr1	160181476	160182939	TTCCTGGAGAGCCACAACAAGCT	6	TTGAGCACATCTTTGAGATCTCCCG	2	PLUS	ILLUMINA	1.507	false	
PIK3CA	NM_006218	6821050	1	2	Homo sapiens	hg19	chr3	178916931	178917517	CAACCGTGAAGAAAAGATCCTCAATCG	1	CATGCCAGTGTGTGAATTTGATATGGT	1	PLUS	ILLUMINA	1.997	false	
PIK3R2	NM_005027	6774659	2	3	Homo sapiens	hg19	chr19	18271339	18271759	TCTGGTGAAGCTTGTGGAGGCCATTGAAA	1	GCGAATCTCACTACCGCCCGGA	1	PLUS	ILLUMINA	1.278	false	
PTEN	NM_000314	6846498	7	8	Homo sapiens	hg19	chr10	89720841	89725083	ACAAAGCCAACCGATACTTTTCTCCA	3	ACAAAAACAGTAGAGGAGCCGTCAA	2	PLUS	ILLUMINA	1.867	false	
RELA	NM_001243985	6824561	3	2	Homo sapiens	hg19	chr11	65429435	65429278	TACCACCAAGACCCACCCCACCATCAA	1	GGCTACACAGGACCAGGGACAGT	7	MINUS	ILLUMINA	1.472	false	
RIPK1	NM_003804	6724347	0	1	Homo sapiens	hg19	chr6	3077187	3078056	ATGAAAACAGTGTACAAGGGGCCCAA	1	GGAGGCGAAGATGATGAACAGAC	7	PLUS	ILLUMINA	1.583	false	
RIPK2	NM_003821	6684466	5	6	Homo sapiens	hg19	chr8	90785026	90792336	CAAAATCCAGATGAAAGACCATCTTTC	1	TTAATAGAACTTGAACCAGTTTTGAGAAC	1	PLUS	ILLUMINA	1.816	false	
SOCS2	NM_003877	6824961	1	2	Homo sapiens	hg19	chr12	93966778	93968523	TCTGGCGAAGGCCCTGCGGGAGCT	2	ATGGTACTGGGGAAGTATGACTGTT	4	PLUS	ILLUMINA	1.423	false	
SOCS3	NM_003955	6973639	1	1	Homo sapiens	hg19	chr17	76353587	76353535	AGCATAGGAAAGCCACATACTCAGC	3	GATGGGTGGAGAGGCTGAGGGACTCA	5	MINUS	ILLUMINA	1.715	false	
STAT1	NM_007315	6638478	1	0	Homo sapiens	hg19	chr2	191878774	191878377	CCGCCTAGCCCTTCCGGATCCT	2	AAGTTTCATTTGCTGTATGCCATCCTC	1	MINUS	ILLUMINA	1.4	false	
STAT5A	NM_003152	6666943	0	1	Homo sapiens	hg19	chr17	40439623	40440117	CAAGACGGTCCCTCCCTGGACTTTTCT	1	CCAGAGCTGGAAGGCGTCGCCAA	1	PLUS	ILLUMINA	1.439	false	
STAT5B	NM_012448	6739147	18	17	Homo sapiens	hg19	chr17	40354392	40353858	TGTCCCCAGGCTCACTATAACATGTA	2	CCTGACTCAGTCCTTGACACCGAT	2	MINUS	ILLUMINA	1.713	false	
TBK1	NM_013254	6713135	19	20	Homo sapiens	hg19	chr12	64891785	64895151	AAAGAACTTGCTGAAAATAACCACATT	1	CATGGATGGTGGCCTTCGCAACGTTGA	1	PLUS	ILLUMINA	1.819	false	
TNF	NM_000594	6633875	1	2	Homo sapiens	hg19	chr6	31544322	31544571	CCTCTCTCTAATCAGCCCTCTGGC	3	ATCATCTTCTCGAACCCCGAGTGACAA	1	PLUS	ILLUMINA	1.696	false	
TNFRSF10A	NM_003844	6766718	3	2	Homo sapiens	hg19	chr8	23060193	23059392	TTGCTTGCCTCCCATGTACAGCTTGTA	1	CCCTGCACCACGACCAGGAACACA	3	MINUS	ILLUMINA	1.633	false	
TNFRSF10B	NM_147187	6691449	8	7	Homo sapiens	hg19	chr8	22884678	22881733	ATGTTGTCCCCCGGGGAGTCAGAGCAT	1	AAGGTCTCAGAGGAGGAGGCTGCT	7	MINUS	ILLUMINA	1.551	false	
TNFRSF10D	NM_003840	6695892	8	7	Homo sapiens	hg19	chr8	22995733	22995479	TGGTTCCAGTGAATGACGCTGACT	3	GGATGCCTCGGCAACACTGGAAGAA	1	MINUS	ILLUMINA	1.588	false	
TNFRSF1A	NM_001065	6670733	1	0	Homo sapiens	hg19	chr12	6450972	6443382	CTCCACCGTGCCTGACCTGCTG	42	TGCTCCTGGAGCTGTTGGTGGGAATATA	1	MINUS	ILLUMINA	1.335	false	
TNFRSF1B	NM_001066	6623911	2	3	Homo sapiens	hg19	chr1	12251112	12251867	TGCTTGAGCTGTGGCTCCCGCTGTA	1	AAGCCTGCACTCGGGAACAGAA	6	PLUS	ILLUMINA	1.238	false	
TNFRSF21	NM_014452	6676676	5	4	Homo sapiens	hg19	chr6	47202438	47200696	CGCTGAGCAGGAACGGTTCCTTTATTA	1	AGTGTTGCGGCAGGTACGCCTG	2	MINUS	ILLUMINA	1.409	false	
TNFRSF9	NM_001561	6665816	8	7	Homo sapiens	hg19	chr1	7993258	7980940	CGGGGCAGAAAGAAACTCCTGTATAT	1	CAAACTACTCAAGAGGAAGATGGCTGT	1	MINUS	ILLUMINA	1.967	false	
TNFSF10	NM_003810	6647296	4	3	Homo sapiens	hg19	chr3	172227041	172224685	GACCAGAGGAAGAAGCAACACATTGT	2	CTCCAAGAATGAAAAGGCTCTGGG	2	MINUS	ILLUMINA	1.73	false	
TNFSF8	NM_001252290	6806112	1	0	Homo sapiens	hg19	chr9	117692423	117680394	TGGCCACTATTATGGTGTTGGTCGTT	1	ACTCCATTCCCAACTCACCTGACAA	2	MINUS	ILLUMINA	1.85	false	
TP53	NM_001126114	6709182	7	6	Homo sapiens	hg19	chr17	7577524	7577127	ACCATCATCACACTGGAAGACTCCA	2	AATCTACTGGGACGGAACAGCTTTG	1	MINUS	ILLUMINA	1.771	false	
TP53BP2	NM_005426	6844165	10	9	Homo sapiens	hg19	chr1	223989841	223988485	CTGGGGCTGCTTCACAAACTAAA	3	TCTAAAATCCATCCAGTTGGCCCTGA	1	MINUS	ILLUMINA	1.6	false	
TP53I3	NM_147184	6803822	2	1	Homo sapiens	hg19	chr2	24307085	24305979	GCCCTGAACCGGGCGGACTTAAT	1	CCTCCAGGAGCCAGCAACATTTT	6	MINUS	ILLUMINA	1.188	false	
TP73	NM_005427	6683610	8	9	Homo sapiens	hg19	chr1	3644754	3645916	TGGAGACGAGGACACGTACTACCTTCA	1	GCGAGGCCGGGAGAACTTTGAGAT	1	PLUS	ILLUMINA	1.664	false	
TRADD	NM_003789	6778390	2	1	Homo sapiens	hg19	chr16	67190445	67189518	CAGTGTACAGGGCTCTGCAGGCT	9	CGGACGTGCTGCAGATGCTGAAGAT	2	MINUS	ILLUMINA	1.391	false	
TRAF2	NM_021138	6832498	1	2	Homo sapiens	hg19	chr9	139793348	139794078	GTACTGCTCCTTCTGCCTGGCCAGCAT	2	AGAACTGTGCTGCCTGTGTTCA	28	PLUS	ILLUMINA	1.338	false	
TRAF3	NM_145725	6683542	10	11	Homo sapiens	hg19	chr14	103369738	103371586	GAGCGCGGGGCAAGTGGCTCGGAACA	1	AGCTGAGCCGGCATGACCAGAT	4	PLUS	ILLUMINA	1.108	false	
TRAF5	NM_145759	6795527	8	9	Homo sapiens	hg19	chr1	211542904	211544687	CAAAAATGGAAGCTTCCTCCCAAACA	2	AAGTCAGCTTGGCTAGAAGCTCA	6	PLUS	ILLUMINA	1.606	false	
TRAF6	NM_145803	6604754	4	3	Homo sapiens	hg19	chr11	36520072	36518776	TGTTTGCACAAGATGGAACTGAGAC	2	ATTGTGAGTTTGCTCTTATGGATTGTCC	2	MINUS	ILLUMINA	1.861	false	
TRAF7	NM_032271	6668780	1	2	Homo sapiens	hg19	chr16	2213975	2215907	TCTTCCCACCCCAGACGTCACCACA	1	ATGGAAACGACCTTCGGACCCG	3	PLUS	ILLUMINA	1.231	false	
XIAP	NM_001204401	6801488	5	6	Homo sapiens	hg19	chrX	123034514	123040865	ATGAGTCAAGTCAGACTTCATTACAGA	3	ATTAGTACTGAAGAGCAGCTAAGGCG	3	PLUS	ILLUMINA	1.951	false	
[Targets]
Gene Name	Transcript ID	Assay ID	Assay Position	Validated	Left Exon	Right Exon	Probe Strand	Target Sequence
ABL1	NM_007313	6607434	FIVE_PRIME	false	1	2	PLUS	CCATTCCCCATTGTGATTATAGCCTAAGACCCGGAGCTTTTCACCTTTAGTTATGCTTAGAGTGTTATCTCCACTGGCC
AIFM1	NM_001130847	6613574	THREE_PRIME	false	16	15	MINUS	TTCATGCTGCTCACCGTCCTTAATGATCTTCCTTGCTATTGGCATTCGGTTAAAGATGTTCC
AKT1	NM_001014432	6694989	CENTER	false	4	3	MINUS	CTCCGTCTTCATCAGCTGGCACTGCGCCACAGAGAAGTTGTTGAGGGGAGCCTCAC
APAF1	NM_181861	6686842	CENTER	false	3	4	PLUS	TTTCCCAACTGAAACCCAATGCACTCCCCCTGGGAAACAACCTTCTAAAAGGGAATGATCTCTAACAGCTTCTGCA
AVEN	NM_020371	6766741	FIVE_PRIME	false	2	1	MINUS	AAACCGGAACTGTGAGAATGAGTCCCCTGCAGAGCTAAGGAGGACACTGAAATCTGTTC
BAD	NM_032989	6717565	THREE_PRIME	false	3	2	MINUS	CTCTTCGGGCGAGGAAGTCCCTTCTTAAAGGAGTCCACAAACTCGTCACTCATCCTCC
BAG1	NM_004323	6814755	CENTER	false	3	2	MINUS	CTTCTTTAGTTCAACCTCTTCCTGTGGACTGTTCTTTTTCCCAATTAACATGACCCGGCAACCATCTT
BAG3	NM_004281	6702665	FIVE_PRIME	false	2	3	PLUS	TGGGAAACAGGTGCAGTTTCTCGATGGGTCATGGGCTGCTGAGGCCTGTCGACCACGGTGTGCACAC
BAG4	NM_004874	6775167	THREE_PRIME	false	3	4	PLUS	TCTGATTGGCTATAGGGGTATGAAGAATCCTTGGGCTGCTGGACTGGGGGTGAAG
BAK1	NM_001188	6828357	FIVE_PRIME	false	1	0	MINUS	GAAGCCATTTTTCAGGTCTCAGTGGAGGACGGGATCAGCCTGCCGGGATCCTGGCCCAACCCGGGTGG
BAX	NR_027882	6728035	FIVE_PRIME	false	0	1	PLUS	TCTTCATGATCTGCTCAGAGCTGGTGGGCCCCCCGCCTCTGGGCTGCTCCCCGGACCCG
BCL10	NM_003921	6712588	FIVE_PRIME	false	1	0	MINUS	CACAGGTATACACGTAAATTTTCTAAGGCGTCCTTCTTCACTTCAGTGAGGTCCT
BCL2	NM_000633	6665875	FIVE_PRIME	false	1	0	MINUS	AGTATTGTTAATATCAGTCTACTTCCTCTGTGATGTTGTATTTTTTAAGTACAGCATGATCCTCTGTCAA
BCL2L11	NM_138623	6656440	FIVE_PRIME	false	0	1	PLUS	CAGAAGGTTGCTTTGCCATTTGGTCTTTTTTTCTTGCGTTTCTCAGTCCGAGAGTCAGAGT
BCL2L13	NM_015367	6753678	FIVE_PRIME	false	0	1	PLUS	AAAAAGGTCTACTTATGGATGTGTAAAACCTGGCCCTGGCCCCTGCCCCAGAAGAGATG
BCL2L2	NM_004050	6813208	FIVE_PRIME	false	2	3	PLUS	AGGGCCCCGTCCCCGTATAGAGCTGTGAACTCCGCCCAGCCCCCACTGCTGTGGATCCAGTCAGCCAG
BCL3	NM_005178	6793284	NA	false	1	2	PLUS	TACCCTGCACCACAGCAATATGGAGAGGCGTGTCTCCGTCCTCATCTGCACGGGTGG
BCLAF1	NM_014739	6630113	THREE_PRIME	false	9	8	MINUS	CGAGAATGATCTTGCTCTCTTTTATGTTTACTGTCATCTTTGTAAGATTTGTATTCCTTGTAA
BFAR	NM_016561	6789292	FIVE_PRIME	false	0	1	PLUS	CGTAGAAAACTGCTGCAAAACATCATTAATCATTCCACTCGTCCCGGGCCAACCGGGCCATTATT
BID	NM_197966	6680411	FIVE_PRIME	false	5	4	MINUS	TTAGCCAGTCACACTTCTGGAACTGTCCGTTCAGTCCATCCCATTTCTGGCTAAGCTCCTCACGTAGGTGCGT
BIK	NM_001197	6713623	CENTER	false	1	2	PLUS	ATCTCGTCCCCGATGCAGGCCAGCCGCAGGGCCAATGCGTCACTGCCCTCCATGCATTCCAAAGAATCGAAGTCC
BIRC2	NM_001166	6703614	CENTER	false	3	4	PLUS	CTCCAGTGGTATCTGAAGTTGACAACAGCTGTTCAAGAAGATGAGGATATCTACCTTGAAT
BIRC3	NM_182962	6764041	NA	false	5	6	PLUS	TGGTCTTCTCCAGGTTCAAAATGGATAATTGATGACTCTGCATTTTCATCTCCTGGGCTGTCT
BIRC5	NM_001012271	6629354	FIVE_PRIME	false	3	4	PLUS	GTTTCCTCAAATTCTTTCTTCTTATTGTTGGTTTCCTTTGCAATTTTGTTCTTGGCTCTTTCTCTGTCCAGTTT
BIRC6	NM_016252	6605793	THREE_PRIME	false	72	73	PLUS	AAGTTTCAGCAACTCTTCGCGGAGCTGAGCAGTGTGACGCTTGAGAGCTGCTGCATGGTGAGAC
BIRC7	NM_139317	6666105	FIVE_PRIME	false	0	1	PLUS	CCCATAGCAGAAGAAGCACCTCACCTTGTCCTGATGGCCTGTGTGGAAGAAGCCGGCAGCAGCCAGC
BNIP2	NM_004330	6716786	THREE_PRIME	false	9	8	MINUS	TTTCGGTTCATCTTGTTTTCCATTAAGTTCTTGATCAACTTGTTTTATGCATTCTGGTATGCCAACGTATTCC
BNIP3	NM_004052	6781677	THREE_PRIME	false	5	4	MINUS	GGTTGTCAGACGCCTTCCAATATAGATCCCCAATCCGATGGCCAGCAAATGAGAGA
BNIP3L	NM_004331	6776815	CENTER	false	2	3	PLUS	GACTTCCTTCTCTCCTTCTACAACTTCTTCTTCTGACTGAGAGCTATGGTCCCTGCTGGTGTGCATT
BOK	NM_032515	6639260	FIVE_PRIME	false	2	3	PLUS	ACACCACCTTGCCCCACGTGATGCCTGCAGAGAAGATGTGGCCAGCCACGGC
BRAF	NM_004333	6678950	FIVE_PRIME	false	1	0	MINUS	TGTCAACTTAATCATTTGTTTGATATTCCACACCTCCTCCGGAATGGCAGGGTCCGCAGCCGAAGAGGCC
CARD6	NM_032587	6718671	FIVE_PRIME	false	1	2	PLUS	TGTTCAAACATAACAGGACATCTTTAAACACCTTTTTTCTTTCTTCTATACTTTTCTCCTGTTCCTCCTCCAATG
CARD9	NM_052814	6800360	FIVE_PRIME	false	1	0	MINUS	ATCGTTCTCGTAGTCCGACATGGCCTCAGCAGGCAGGCTGAGGGTCTTCCAGGAGCCACCTGCACTGCAG
CASP1	NM_033292	6735042	THREE_PRIME	false	9	8	MINUS	AACCTTTACAGAAGGATCTCTTCACTTCCTGCCCACAGACATTCATACAGTTTCCTT
CASP10	NM_032977	6713238	FIVE_PRIME	false	0	1	PLUS	TGTTGACCTTGAGATTTCATGGCCAGCCTTCAGATCAAGCTCCACCAATCTTCTGGAAGTAA
CASP14	NM_012114	6769691	FIVE_PRIME	false	0	1	PLUS	TTGTGAGTCCCGGCTCTCAGCACCCTTGTCTGATCCAACTCTAGAGGCAGCTGTTCCTCAAGGCCAAGTT
CASP2	NM_001224	6695810	FIVE_PRIME	false	1	2	PLUS	AAGTTGAGGAGTTCCACATTCTGGCTGAAACTGCCCACTTTGGCCTGGATGAGCTCCCTCATTTCCAAGGTGA
CASP3	NM_004346	6622272	THREE_PRIME	false	7	6	MINUS	GATGAACCAGGAGCCATCCTTTGAATTTCGCCAAGAATAATAACCAGGTGCTGTGGAGTATGCATACAAGAAGTCGG
CASP4	NM_033306	6612269	NA	false	6	5	MINUS	GATGAAGATAGAGCCCATTGTGCTGTCTCTCCAGGACACGTTGTGTGGCGTTGAAGAGCAGAAAGCAATGAAGTC
CASP5	NM_004347	6800318	THREE_PRIME	false	9	8	MINUS	AGAGGAGGGCTGGGCTGCCTGTGGTTTCATTTTCAATTGCCAGGAAAGAGGTAGAAATCTCTT
CASP6	NM_001226	6764405	FIVE_PRIME	false	5	4	MINUS	AATGACTGGCACATCGTGCTGGTTTCCCCGACATGCCTGAATGATAAATATCTTGGGTTTTCCAACCAGGC
CASP7	NM_033340	6688018	FIVE_PRIME	false	1	2	PLUS	TCTTGATGGATCGCATGGTGACATTTTTCTTCTTCTTACTGAAGAGGGACGGTACAAACGAGGACCGGTCT
CASP8	NM_033355	6847575	FIVE_PRIME	false	3	4	PLUS	CCATCTCTATGAAAATATCCAGCAGGTTCATGTCATCATCCAGTTTGCATTTGGAGATTTCCT
CASP8AP2	NM_012115	6769661	CENTER	false	5	6	PLUS	TTGCAGTTTTATGATTATTTCGAAAATGTGGAAACTCAGACAATCTTTGGTGAAGATTACTTATTTCTTCATCCTTGCG
CASP9	NM_032996	6776537	THREE_PRIME	false	8	7	MINUS	CCTTTCACCGAAACAGCATTAGCGACCCTAAGCAGGAGGGACTGCAGGTCTTCAGAG
CD27	NM_001242	6816931	FIVE_PRIME	false	0	1	PLUS	CTTTCTATGCTGGTCACAGTCCTTCACGAGGAATGTTCCTGGCTCACACATCTGGCAGCACAGCTTT
CD40	NM_001250	6615876	FIVE_PRIME	false	1	2	PLUS	TCTGTGCAGTCACTCACCAGTTTCTGTCCTGGCTGGCACAAAGAACAGCACTGACTGTT
CD70	NM_001252	6775017	FIVE_PRIME	false	1	0	MINUS	ATTCAGCTGCAGCTCAGCTACGTCCCACCCAAGTGACTCGAGCGGCAGCTGCTGC
CFLAR	NM_003879	6709279	THREE_PRIME	false	3	4	PLUS	ATTCCTGTAACTTGTCCCTGCTCCTTGAACAGACTGCTTGTACTTCTGGATTTTTGTCTTCAGG
CIDEA	NR_036468	6751245	FIVE_PRIME	false	1	2	PLUS	AGAGTGACCAGTCCGGTAGCGATGACGAGGGCATCCAGAGTCTTGCTGATGAGCTCCTGCAGGCTGCTTGCCAT
CIDEB	NM_014430	6612266	THREE_PRIME	false	6	5	MINUS	AGTGTGGAGGTCCAACGAAGGAGCTCCCTGAGTACTTTCTTTGGGCCAAGTCC
CRADD	NM_003805	6838464	FIVE_PRIME	false	0	1	PLUS	ACTTGTTTGTCTCTGGCCTCCATTTCTCCGTCTGCAACCACGTATCTTTGGGGCGGGG
CYCS	NM_018947	6764133	FIVE_PRIME	false	1	0	MINUS	CTTCTTGCCTTTCTCAACATCACCCATATTTAATTCTCTTTTTAGTCGCTGGCACAACGAACACTC
DAPK1	NM_004938	6827954	THREE_PRIME	false	24	25	PLUS	AGCAGCACGTCCTGAACTGTTTCACTTTGCATGATGTTGATCTCGCCTGTGCTGTGGAGCTGCTGAGCAATGCGCCTGAGGT
DAXX	NM_001350_4	6675987	FIVE_PRIME	false	3	2	MINUS	GCCAACACAGGATCTGATAGTGCAGGGTCAACGCCTGGCCTATAGTCATCTGTGAGGTGGCAGCC
DEDD	NM_032998	6621603	THREE_PRIME	false	5	4	MINUS	AGTCTCATGCTGGCAGTATTCAGCCCGAACCCGCAGTCTGATGTCACATGTCTGCTTCTCCTTGGGATCTGGTGTCA
DEDD2	NM_133328	6841178	CENTER	false	3	2	MINUS	GACTCCGCCGCTGCCGCTTGGTTGGGGGGGAGCCTGTCTCCCACTGACCCTGCTGAGAATTT
DFFA	NM_004401	6690106	CENTER	false	3	2	MINUS	TAGTTCCTGAGCCAGGTCTGAGCAGGGAGCGTCAACAAGCATCTGGAGGTCCTCCTCTGATAGGAGGATGATGCT
DIABLO	NR_024600	6805154	CENTER	false	5	4	MINUS	GTGGTTTCCAGCTTCAAGTACTCTTGGTGTTTTGAAGTCATCTCAGCTCTGGCTCCTATGATCACCTGCCACAC
FADD	NM_003824	6974570	THREE_PRIME	false	1	1	PLUS	ACTGCTCATCTGCACAGATTCCTTCTGTGCTGGACACGGTTCCAACTTTCCAACTA
FAS	NM_000043	6886514	NA	false	8	NA	PLUS	ATGACACCAATAAACTGTGCAAAGGTCTTTGAGGTAGAGCCTTATTTAAATTCTGC
FASLG	NM_000639	6690598	THREE_PRIME	false	2	3	PLUS	AGAGGCATGGACCTTGAGTTGGACTTGCCTGTTAAATGGGCCACTTTCCTCAGCTCC
HIP1	NM_005338	6761552	NA	false	10	9	MINUS	ATATGTTCTGACAGGGCTGAGGCTCGCAGGAAGTTGGGTGGGTTCTCAGGCAGCTGGGGGATCTGAATGAGCCGCTT
HMGB1	NM_002128	6680865	THREE_PRIME	false	4	3	MINUS	CTTTCCTTTAGCTCGATATGCAGCAATATCCTTTTCATATTTTTCCTTCAGCTTCGCAGCCTTCTTTTCATAA
HRK	NM_003806	6681306	FIVE_PRIME	false	1	0	MINUS	TTCTCCAAGGACACAGGGTTTTCACCAACCTGTTGCTCGCTCCGGCTGGGTCTCGGC
HSP90B1	NM_003299	6657454	FIVE_PRIME	false	0	1	PLUS	GTACCATCCACATCAACTTCATCGTCAGCTCTGACCGACCCGAAGGTCAGCAGGACGCAGCAGAGGCCCAGCA
IGF1R	NM_000875	6821131	FIVE_PRIME	false	2	3	PLUS	AGACCTTCGGGCAAGGACCTTCACAAGGGATGCAGTACATGCTCTGGCTGCCGTTGCGGATGAAGCCCGAGG
IKBIP	NM_201612	6720992	FIVE_PRIME	false	1	0	MINUS	GGTTTTCCACCTTTGCAAATTTTTCTGACTGCTGAAATACAAACCAGGCCAGGCCCAGGCACGTCCCCAGCGACAGC
IKBKB	NR_040009	6639731	NA	false	5	6	PLUS	AGCTCCTTGGCATATCCTAGGTCAATAATTTTGTGTATTAACCTCTGTTCTCCTTGCTGCAGGACGATGTTT
IKBKG	NM_003639	6701312	FIVE_PRIME	false	1	2	PLUS	AGAATCTGGTTGCTCTGCCGGATGGCATCTCGGAGCTCTTGATTCTCCTCCAGGCA
IL10	NM_000572	6739478	CENTER	false	3	2	MINUS	CTTGTTTTCACAGGGAAGAAATCGATGACAGCGCCGTAGCCTCAGCCTGAGGGTC
IL1A	NM_000575	6634703	FIVE_PRIME	false	1	0	MINUS	TGTCTGGAACTTTGGCCATCTTGACTTCTTTGCTGACTCAAACGCCAATGAAATGACTCCCT
LTA	NM_000595_3	6914026	NA	false	3	NA	PLUS	TCATCCCCCAAGCTCCTCCATGTGCCTGCTCTTCCTCTGTGTGTGGATCTAGGCCCCA
LTB	NM_002341_3	6849823	NA	false	1	0	MINUS	TGTGCCCCGGGGTCGGCCGTCTCCGTTACCAGTCCTCCCTGATCCTGGGGCACTA
LTBR	NM_002342	6732979	FIVE_PRIME	false	2	3	PLUS	TTGTGCAGGGGGCAATCTCCTCGAGGCCCATCACTGGGTCACAGGGGCGGCACAGCTGGCAG
MCL1	NM_001197320	6687379	THREE_PRIME	false	3	2	MINUS	TCTACATGGAAGAACTCCACAAACCCATCCCAGCCTCTTTGTTTAACTAGCCAGTCCCGTTTTG
MYC	NM_002467	6670402	THREE_PRIME	false	1	2	PLUS	CGATTTCTTCCTCATCTTCTTGTTCCTCCTCAGAGTCGCTGCTGGTGGTGGGCGGTGTCTCCTCA
NAIP	NM_004536	6834644	THREE_PRIME	false	16	15	MINUS	GTTTCTGGAAACCTCCACTGATTGCTACTTTGGCAATTTCCACCACGCTGTCATCATTCAAAGTCT
NFKB1	NM_003998	6777413	CENTER	false	5	6	PLUS	CTTTGTCACATGAAGTATACCCAGGTTTGCGAAGCCGACCACCATGTCCTTGGGTCCAGCAGT
NFKB2	NM_002502	6830412	THREE_PRIME	false	19	20	PLUS	AGCTGTATCACCAAGTGACAGTCCCGGCCCTGCTGGGCTGGGCGGGGTCAGGGGTGG
NFKBIA	NM_020529	6810000	THREE_PRIME	false	5	4	MINUS	CTCCAAACACACAGTCATCATAGGGCAGCTCGTCCTCTGTGAACTCCGTGAACTC
NOD1	NM_006092	6622684	THREE_PRIME	false	13	12	MINUS	CTCCTCTGGTTTTATCAGGTTTCCATTTAGGCAAATCTCTGTTATGCCAGTGTTGCTCTGTAACGC
NOL3	NM_001185058	6816005	FIVE_PRIME	false	4	5	PLUS	ATGGGCGGGGCACCGCCTGTCAGAGCTCTGGCCTTCAGGAATCTTCGGACTCGTCCCTTTCCTCGAAGTCGGGCTCGGGCTCT
PEA15	NM_003768	6787860	CENTER	false	1	2	PLUS	CGGGAGATCTCAAAGATGTGCTCAATGTAGGAGAGGTTGTCTTTGTCCAGCTTGTTGTGGCTCTCCAGGAA
PIK3CA	NM_006218	6821050	CENTER	false	1	2	PLUS	ACCATATCAAATTCACACACTGGCATGCCGATAGCAAAACCAATTTCTCGATTGAGGATCTTTTCTTCACGGTTG
PIK3R2	NM_005027	6774659	FIVE_PRIME	false	2	3	PLUS	TCCGGGCGGTAGTGAGATTCGCTGTCCAGCCCTGTCCTTTCAATGGCCTCCACAAGCTTCACCAGA
PTEN	NM_000314	6846498	THREE_PRIME	false	7	8	PLUS	TTGACGGCTCCTCTACTGTTTTTGTGAAGTACAGCTTCACCTTAAAATTTGGAGAAAAGTATCGGTTGGCTTTGT
RELA	NM_001243985	6824561	FIVE_PRIME	false	3	2	MINUS	ACTGTCCCTGGTCCTGTGTAGCCATTGATCTTGATGGTGGGGTGGGTCTTGGTGGTA
RIPK1	NM_003804	6724347	FIVE_PRIME	false	0	1	PLUS	GTCTGTTCATCATCTTCGCCTCCTCCAAGAGGGCCTCGTTGTGCTCAATGCAGTTGGGCCCCTTGTACACTGTTTTCAT
RIPK2	NM_003821	6684466	CENTER	false	5	6	PLUS	GTTCTCAAAACTGGTTCAAGTTCTATTAAACATTTTAAGAAAGATGGTCTTTCATCTGGATTTTG
SOCS2	NM_003877	6824961	FIVE_PRIME	false	1	2	PLUS	AACAGTCATACTTCCCCAGTACCATCCTGTCTGACCGAGCTCCCGCAGGGCCTTCGCCAGA
SOCS3	NM_003955	6973639	FIVE_PRIME	false	1	1	MINUS	TGAGTCCCTCAGCCTCTCCACCCATCCAGGCTGAGTATGTGGCTTTCCTATGCT
STAT1	NM_007315	6638478	FIVE_PRIME	false	1	0	MINUS	GAGGATGGCATACAGCAAATGAAACTTTTCTGCGCGCAGGATCCGGAAGGGCTAGGCGG
STAT5A	NM_003152	6666943	FIVE_PRIME	false	0	1	PLUS	TTGGCGACGCCTTCCAGCTCTGGCGCGTGTCATCTTTTGAGCCCCTTCAGAAAAGTCCAGGGAGGGACCGTCTTG
STAT5B	NM_012448	6739147	THREE_PRIME	false	18	17	MINUS	ATCGGTGTCAAGGACTGAGTCAGGGTTCTGTGGGTACATGTTATAGTGAGCCTGGGGACA
TBK1	NM_013254	6713135	THREE_PRIME	false	19	20	PLUS	TCAACGTTGCGAAGGCCACCATCCATGGTTAAAGAGCCAAACCTTTCTAAAATGTGGTTATTTTCAGCAAGTTCTTT
TNF	NM_000594	6633875	FIVE_PRIME	false	1	2	PLUS	TTGTCACTCGGGGTTCGAGAAGATGATCTGACTGCCTGGGCCAGAGGGCTGATTAGAGAGAGG
TNFRSF10A	NM_003844	6766718	CENTER	false	3	2	MINUS	TGTGTTCCTGGTCGTGGTGCAGGGACTTCTCTCTTCTTCATCTGATTTACAAGCTGTACATGGGAGGCAAGCAA
TNFRSF10B	NM_147187	6691449	NA	false	8	7	MINUS	AGCAGCCTCCTCCTCTGAGACCTTTCAGCTTCTGCCGGTTCCAGCAGATGCTCTGACTCCCCGGGGGACAACAT
TNFRSF10D	NM_003840	6695892	THREE_PRIME	false	8	7	MINUS	TTCTTCCAGTGTTGCCGAGGCATCCAGCAAGGTGCTGATGTCAGCGGAGTCAGCGTCATTCACTGGAACCA
TNFRSF1A	NM_001065	6670733	FIVE_PRIME	false	1	0	MINUS	TATATTCCCACCAACAGCTCCAGGAGCACCAGTGGCAGCAGCAGGTCAGGCACGGTGGAG
TNFRSF1B	NM_001066	6623911	FIVE_PRIME	false	2	3	PLUS	TTCTGTTCCCGAGTGCAGGCTTGAGTTTCCACCTGGTCAGAGCTACAGCGGGAGCCACAGCTCAAGCA
TNFRSF21	NM_014452	6676676	THREE_PRIME	false	5	4	MINUS	CAGGCGTACCTGCCGCAACACTGTGTCCTTCTTTTCTTTGGTAATAAAGGAACCGTTCCTGCTCAGCG
TNFRSF9	NM_001561	6665816	THREE_PRIME	false	8	7	MINUS	ACAGCCATCTTCCTCTTGAGTAGTTTGTACTGGTCTCATAAATGGTTGTTTGAATATATACAGGAGTTTCTTTCTGCCCCG
TNFSF10	NM_003810	6647296	FIVE_PRIME	false	4	3	MINUS	CCCAGAGCCTTTTCATTCTTGGAGTTTGGAGAAGACAATGTGTTGCTTCTTCCTCTGGTC
TNFSF8	NM_001252290	6806112	FIVE_PRIME	false	1	0	MINUS	TTGTCAGGTGAGTTGGGAATGGAGTCCGTCCTCTGAACGACCAACACCATAATAGTGGCCA
TP53	NM_001126114	6709182	THREE_PRIME	false	7	6	MINUS	CAAAGCTGTTCCGTCCCAGTAGATTACCACTGGAGTCTTCCAGTGTGATGATGGT
TP53BP2	NM_005426	6844165	NA	false	10	9	MINUS	TCAGGGCCAACTGGATGGATTTTAGAGCCTTTAGTTTGTGAAGCAGCCCCAG
TP53I3	NM_147184	6803822	FIVE_PRIME	false	2	1	MINUS	AAAATGTTGCTGGCTCCTGGAGGTGGGTCATACTGGCCTTGTCTCTGCATTAAGTCCGCCCGGTTCAGGGC
TP73	NM_005427	6683610	THREE_PRIME	false	8	9	PLUS	ATCTCAAAGTTCTCCCGGCCTCGCACCTGAAGGTAGTACGTGTCCTCGTCTCCA
TRADD	NM_003789	6778390	FIVE_PRIME	false	2	1	MINUS	ATCTTCAGCATCTGCAGCACGTCCGGGCTCCCGCCGCTCTCTGCCAAGGCAGCCTGCAGAGCCCTGTACACTG
TRAF2	NM_021138	6832498	FIVE_PRIME	false	1	2	PLUS	TGAACACAGGCAGCACAGTTCTGAGGCCCAGAGCTGAGGATGCTGGCCAGGCAGAAGGAGCAGTAC
TRAF3	NM_145725	6683542	THREE_PRIME	false	10	11	PLUS	ATCTGGTCATGCCGGCTCAGCTGGGACTCCAGCAGGCCTGTGTTCCGAGCCACTTGCCCCGCGCTC
TRAF5	NM_145759	6795527	THREE_PRIME	false	8	9	PLUS	TGAGCTTCTAGCCAAGCTGACTTGTCAATGTGACTGGCAAAAACCTGGATGTTTGGGAGGAAGCTTCCATTTTTG
TRAF6	NM_145803	6604754	FIVE_PRIME	false	4	3	MINUS	GGACAATCCATAAGAGCAAACTCACAATGTGCTTGATGATCCTCAAGATGTCTCAGTTCCATCTTGTGCAAACA
TRAF7	NM_032271	6668780	FIVE_PRIME	false	1	2	PLUS	CGGGTCCGAAGGTCGTTTCCATTCTGGTCCCTGTGGTGACGTCTGGGGTGGGAAGA
XIAP	NM_001204401	6801488	THREE_PRIME	false	5	6	PLUS	CGCCTTAGCTGCTCTTCAGTACTAATCTCTTTCTGTAATGAAGTCTGACTTGACTCAT
